ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
ETCR2000A+ Digital Clamp Ground Resistance Tester - 0.010Ω to 200Ω Range, USB Data Interface, Double Insulation - Perfect for Electrical Maintenance, Solar Panel Installation & Industrial Safety Testing
$162.25
$295
45% Off
Quantity:
Delivery & Return: Free shipping on all orders over $50
Estimated Delivery: 10-15 days international
20 people viewing this product right now!
SKU: 44596623
Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay
shop
Description
Overview ETCR2000A+ Clamp Earth Resistance Tester is our company's technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in: Breakthrough in self-test the boot a long time to waiting, start immediately into the test.Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology.Breakthrough the old product too heavy issues, more in line with characteristics of hand-held devices.New design, panel operation with 6 buttons, better performance.Increase sound and light alarm function, with "beep-beep-beep” alarm sound.Increase the interference signal recognition indicator function, with "beep-beep-beep” indicator.Measurement range: 0.01Ω-200ΩStored data 99 Units. Lower power consumption, Maximum operating current less than 50mA. ETCR2000A+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance. Field Application The application of machine room earth resistance measurement The machine room of telecommunication system normally in the upper deck of the building. It is hard to use the meg-ohm meter to measure. However, ETCR Clamp meters are very convenient to test. The application of substation earth resistance measurement ETCR series clamp meter can use to test the situation of contact and connect of circuit. With the help of one test line, it can be used to test the connect situation of equipment in station and the grounding system. The application of building lightning protection grounding system measurement If the earth poles of the building are independent of each other, the earth resistance can be measured by clamp to testing any of the earth poles, and the earth resistance can also be measured by clamp the building roof lightning arrester.When the measured value is less than the allowable value, the earth electrode is qualified.If the measurement value of the clamp meter is larger than the allowable value, please use ingle earth point method to measurement. From the measuring principle, ETCR series Meter can only measure the loop resistance, the single-point grounding is not measured. However, users are able to use a testing line very near to the earth electrode of the grounding system to artificially create a loop for testing. For details, please read user manuals. ETCR2000A+ Ground Resistance Meter Technical Specifications Function Ground resistance test, Loop resistance test Resistance Range 0.01-200Ω Resistance Resolution 0.001Ω Power Supply 6VDC 4 PCS of LR6 lkaline batteries Clamp Size 65mm×32mm Clamp Opening Extent 32mm Accuracy ±1%±0.01Ω Data Storage 99 sets Alarm Threshold Setting Range Resistance: 1-199Ω Alarm Sound and Light “Beep-beep-beep” alarm tone, Alarm Symbol Flashing, Press AL key to turn on, turn off Alarm or set Alarm Threshold. Interference Signal Recognitio “Beep-beep-beep” tone, NOISE symbol blinking Working Environment -20℃~55℃ 20%rh~80%rh Store Environment -20℃~60℃; below 90%rh LCD Screen 4 Digits LCD display, Screen L×W: 47mm×28.5mm Tester Weight 1160g (With batteries) Clamp Dimension L×W×T:285mm×85mm×56mm Protection Level Double insulation Structural Feature Clamp CT Shift Automatic shift External Magnetic Field 1KHz Measured Current Frequency 50/60Hz Automatic Low Battery Voltage Indicator When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed Memory Full Indication MEM symbol blinks when all 99 sets memory is full Over Range Indication Out of range indication “OLΩ”, "L0.01” or “OL A” Auto Power-off 5 minutes after Boot up Power Consumption Max 50mA either in booting up or normally working, Continuously working for 30 hours Data Upload & Monitoring Software 1. Data Upload This listing of ETCR2000A+ ground resistance meter features USB interface. Users can upload data with such function.Boot up and enter test state, connect the computer with USB cable, and run the monitoring software. If the communication is normal, the computer can monitor the online resistance in real time.The monitoring software has functions such as online real-time monitoring, historical query, software alarm setting, historical data reading, and review, saving, and reporting.Historical data can optionally be saved in TXT text or Word format. 2. Monitoring Software Monitoring software can be installed or used directly. Click SETUP icon to install according to steps; or go to the SUPPORT folder and click the icon to run the software directly.The monitoring software has the function of automatically scanning serial port number and connecting, no need to manual setting serial port number.In real-time monitoring, can pause, stop, continue and switch the present mode. historical data can be accessed and saved.The software could set alarm threshold value of the resistance or current, check and turn on the alarm. If larger than the setting value, the alarm light will flashes. If the meter is offline or stops real-time monitoring, indicates "STOP". If you encounter the following scenarios, we kindly request that you seek support from us for assistance with software download: Absence of a software CD within the packaging.Lack of an optical drive in your computer. ETCR2100A+ ETCR2100+ ETCR2100C+ ETCR2000A+ ETCR2000+ ETCR2000C+ Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Customer Reviews — — — — — — Price $197.99$197.99 $303.00$303.00 $445.00$445.00 $295.00$295.00 $350.00$350.00 $467.00$467.00 Clamp Size Φ32mm Φ32mm Φ32mm 65mm×32mm 65mm×32mm 65mm×32mm Resistance Range 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω Current Range ✘ ✘ 0.00mA~20.0A ✘ ✘ 0.00mA~20.0A USB Interface ✓ ✓ ✓ ✓ ✓ ✓ ETCR2100A+ ETCR2100+ ETCR2100C+ ETCR2000A+ ETCR2000+ ETCR2000C+ Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Customer Reviews 4.4 out of 5 stars 113 4.6 out of 5 stars 40 4.8 out of 5 stars 9 4.3 out of 5 stars 11 — — Price $156.50$156.50 $218.00$218.00 $365.00$365.00 $187.00$187.00 $308.75$308.75 $367.00$367.00 Clamp Size Φ32mm Φ32mm Φ32mm 65mm×32mm 65mm×32mm 65mm×32mm Resistance Range 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω Current Range ✘ ✘ 0.00mA~20.0A ✘ ✘ 0.00mA~20.0A USB Interface ✘ ✘ ✘ ✘ ✘ ✘
More
Shipping & Returns

For all orders exceeding a value of 100USD shipping is offered for free.

Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.

Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.

Features

Important Notice Designed to measure loop resistance only, not single-point grounding. Users can create an artificial loop near the grounding electrode for testing. Refer to the user manual for detailed instructions

Wide Application Ideal for measuring grounding resistance in power, meteorology, oilfields, construction, and industrial electrical equipment. No need to break down grounding leads or use auxiliary electrodes for loop system measurements

Advanced Functionality Measures ground faults undetectable by traditional methods, making it suitable for applications where conventional meters fail. Accurately measures the combined resistance of the grounding body and lead

Measurement Range Offers a wide measuring range from 0.010Ω to 200Ω with a high resolution of 0.001Ω. The clamp size is 65mm×32mm, ensuring versatility in various testing scenarios

Precision Measurement Utilizes loop resistance measurement, combining voltage and current coils. It measures induced potential and current to calculate resistance using the formula R=E/I for precise results

USB Interface The ETCR2000A+ ground resistance meter features a USB interface for easy data upload. Simply connect to a computer with a USB cable after boot-up, and run the monitoring software to view real-time resistance data

Advanced Software Functions The monitoring software offers real-time monitoring, historical data query, alarm settings, and data review. Users can save historical data in TXT or Word format for easy reporting and analysis

Easy Software Installation Install the monitoring software with a simple click of the SETUP icon, or run it directly from the SUPPORT folder without installation. It’s designed for user convenience and quick setup

Enhanced Monitoring Features The software automatically scans and connects to the serial port, requiring no manual settings. It allows pausing, stopping, and resuming of real-time monitoring, with easy access to historical data

Customizable Alarms Set alarm thresholds for resistance, and the software will alert you if values exceed the set limit. If the meter goes offline or stops monitoring, the software indicates "STOP" for clear status updates